Multi-Parameter Patient Monitor NEUMP16
$1,195.00$1,295.00 (-8%)
1.Advance patient Manage: gender, full name, ID no., room no., bed no., weight, height, blood type, paced or not, remakes;
2.Multi-parameter board: Separated parameter board, main board, ECG board, SPO2 board, and NIBP board are independent;
3.Interface: Color, layout of each parameters can be set up by user need, bed to bed view display(optional);
4.Fanless: Use special fanless cooling technology in the device to provide users quiet environment;
5.Standby: Unique standby mode for energy saving and suspend monitoring;
6.Time delay: Time delay switch-off function to save data when monitor turn off suddenly;
9.Easy software update: Users can update monitor software by themselves;
10.Analysis: Real time S-T segment analysis, and 20 type arrhythmic analysis; SpO2 Pitch Tone Variation, Drug Dose Calculation and Hemodynamic Calculations;
11.Storage: external SD card slot enables memory extension(optional);
12.Data transfer: USB port to allow to transfer patient data to a PC (optional);
13.Special SINNOR F-6 Spo2 technology: which is as correct as Nellcor spo2 but cheaper than it(optional);
14.Resistance to interference : Efficient resistance to interference of defibrillator and HF knife;
15.Other optional: Touch Screen, Printer, Wall amount, VGA connect
Specifications
Patient monitor | hospital monitor MSLMP16
ECG |
Lead mode: 5 –lead(R, L, F, N, C) (3/12 lead ECG for optional)
Lead selection: I, II, III, avR, avL, avF, V Waveform: 3 and 7 channel selectable Gain selection: 0.5mm/mv,1mm/mv,2mm/mv Sweep speed: 6.25mm/s;12.5mm/s;25mm/s;50mm/s Heart rate range: Adult: 15~300bpm; Neonate/pediatric: 15~350bpm Accuracy: +1bpm or +1%, which is greater Resolution: 1bpm Filter: surgery mode: 1~20Hz Monitor model: 0.5~40Hz Diagnostic mode: 0.05~130Hz Scaling signal: 1mv, +3% Protection: withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation Alarm range: 15~350bpm S-T segment detection: Measurement range: 2.0mV~+2.0mV Alarm Range: -2.0mV~ +2.0mV Accuracy: -0.8mV ~+0.8Mv Error: +0.02Mv
Arrhythmia analysis: YES |
SPO2 |
Measurement range: 0~100%
Wave speed: 12.5mm/s;25mm/s Resolution: 1% Accuracy: +2% (70-100%); 0-69% unspecified Alarm range 0~100% Lower perfusion situation
|
Pulse Rate(PR) |
Range: 20~300bpm
Resolution: 1bpm Error: +1bpm or +2%, whichever is greater
|
NIBP |
Method: Digital Automatic oscillometric
Operation mode : Manual/Automatic Auto measurement time: Adjustable (1~720min) (1,2,3,4,5,10,15,30,60,90,120,240,480,720min) Measurement Unit: mmHg/Kpa selectable Measurement types: Systolic, Diastolic, Mean Measurement Range: Range of Systolic pressure: Adult: 40~270mmHg Pediatric: 40~220mmHg Neonate: 40~135mmHg Range of mean pressure: Adult: 20~235mmHg Pediatric: 20~165mmHg Neonate: 20~110mmHg Range of diastolic pressure: Adult: 10~215mmHg Pediatric: 10~150mmHg Neonate: 10~100mmHg Over-pressure protection: Double safety protection Resolution: 1 mmHg Alarm: Systolic, Diastolic, and Mean
|
RESPIRATION |
Method: RA-LL impedance
Measurement range: Adult: 7~120rpm; Neonate/Pediatric: 7~150rpm Apnea alarm: YES, 10~40s Resolution: 1rpm Accuracy: +2rpm
|
TEMPERATURE |
Compatible probe: YSI or CYF
Measurement range: 5~50℃ Resolution: 0.1℃ Accuracy: +0.1℃ Refreshing time: about 1 Average measuring time: <10s
|
Accessories supplies
1. 5 lead ECG cable 1set
2. Adult Spo2 probe 1set
3. Adult NIBP Cuff and extension tube 1set
4. Temp probe 1set
5. Ground connecting liner 1set
6. ECG Chest electrode (10pcs/pack) 1pack
7.2200mA lithium battery 1PCS