Intelligent Microwave Digestion System Extractor NEUEX06
$27,700.00
- Special Designed Sample Digestion Vessel
The automatic vent and sel-resealing stucture which won national patent ensures the digestion vessels can automatcall release pressure and instanty reseal when a sudden over-pressure situation occurs. t prevents waste of batch samples and solutons and alsoavoids vessel damage. - Contact-less Temperature and Pressure Monitoring System
The advanced cortactHless IRsensor could measure the rea-time temperature of sample solutions in each digestion vessel.Meanwile, the contact-less pressure sensor could mornitor the real-time pressure of each vessel. This realizes isolation between temperature and pressure controlling system, also avoids sample cross-contamination.Each real-time temperature and pressure value is displayed during the whole digestion process, allowing a clear check of digestion conditions. - Large Storage Capacity
lt can edit and store 255 types of programs according to user’s requirements and each method program can set parameters(temperature, pressure, time, microwave power) according to their own requirements which provides convenient operation for users. - Safety Protection System
With light-stengh double locked security door, the real-time temperature and pressure monitoring, automatic adjustment of over-pressure and over-temperature and abnormal sound monitoring, the device can run in a highly safe environment. - Power Adjustment
The variable frequency resonance or non-pulse(optional) contiues rotating mode ensures high efficient and even mlcrowave throughput t can be set between O~300oW according to user’ s requirements.
Specifications
Features:
1.Special Designed Sample Digestion vessel
The automatic vent and self resealing structure which won national patent ensures the digestion vessels can automatically release pressure and instantly reseal when a sudden over-pressure situation occurs. It prevents waste of batch samples and solutions and also avoids vessel damage.
2.Contact-less Temperature and Pressure Monitoring System
The advanced contact H less IR sensor could measure the real-time temperature of sample solutions in each digestion vessel Meanwhile, the contact-less pressure sensor could monitor the real-time pressure of each vessel. This realizes isolation between temperature and pressure controlling system, also avoids sample cross-contamination. Each real-time temperature and pressure value is displayed during the whole digestion process, allowing a clear check of digestion conditions.
3.Large Storage Capacity
It can stand store 25 types of programs according to user’s requirements and each method program can set parameters (temperature, pressure, time, microwave power) according to their own requirements which provides convenient operation for users.
4.Safety Protection System
With high-strength double locked security door, the real-time temperature and pressure monitoring, automatic adjustment of over-pressure and over-temperature and abnormal sound monitoring, the device can run in a highly safe environment.
5.Power Adjustment
The variable frequency resonance or non-pulse(optional) continues rotating mode ensures high efficient and even microwave throughput It can be set between 0~3oooW according to user’ s requirements.
Parameters:
Pressure Control:12 vessels /18vessels
Vessel volume:100 ml
Temperature Monitoring: Contactless IR sensor
Display:7 inches Touch Screen
Maximum Working Pressure:6MPA
Temperature Control Range:50~400℃
Dimension:640*630*590mm
Maximum Working Temperature:250℃
Inner Vessel Temperature Limit:300℃
Rotation Mode:360 Continuous Rotation
Microwave Power:0-3000W Adjustable/O-200OW Adjustable
Temperature Control: Scanning control of each vessel
Pressure Testing: Contactless pressure sensor
Vessel material: Inner: Imported TFM, Outer: Imported PEEK + Glass Fiber
Pressure Control range:0-10MPA
Pressure Control Accuracy:0.01MPA
Power:AC220V,16A,50/60HZ
Weight:70KG
Temperature Control Accuracy:+0.3℃
Microwave Frequency:2450HZ
Microwave Leak:<5mwlcm2
Pressure Control | 12 vessels /18wessels |
vessel volume | 100 mil |
Temperature Monitoring | Contactless lR sensor |
Display | 7inches Touch Scrcan |
Maximum Working Pressure | 6 MPA |
Temperature Control Range | 50~400c |
Dimension | 640″630*590mm |
Maximurm Working Temperatur | 25orc |
lnner vessel Temperature Limit | 3oorc |
Rotation Mode | 360 Coritinuous Rotation |
Microwave Power | 0-300OW Adjustable/0-20O0W Adjustalble |
Temperature Control | Scanning controil of each vessel |
Pressure Testing | Contactless pr8ssure sansor |
vessel material | lrmar.lmpoupms TM oue importmd FEEN+oassFter |
Pressurs Controll range | 0-10MPA |
Pressure Controll Arcuracy | 0.01MPA |
Pawer | Ac 220,16A,50VB0Hz |
Weight | 70KG |
Temperature Conroll_cCuracp | 10.3℃ |
icraweve Frequency | 2450Hz |
Microweve Leak | <5mwdlom2 |