Roll over image to zoom in
Digital Colposcope Video Machine NEUCE09
$8,990.00$9,700.00 (-7%)
1.High Resolution and Definition Camera System
2.Perfect combination of optical and digital system, clearer view;
3.Synchronous observation through the optical scope and the computer;
4.1/3”high resolution, color CCD
5.5 speed Optical Amplification;
6.Video output;
7.Built-in scale in the observation system to measure the lesion size;
8.White balance auto-adjusted;
9.Unique spectral grating and fine-tuning
10.With a green filter, to facilitate observation of capillary lesions.
11.Unique Light Source Design
12.lWith integrative halogen light source and ring fiber, more brighter, and brightness can be adjusted;
13.Special Swing Arm
14.Stand with damping resistance design, easy adjustment at any angle (Very flexible and convenient);
15.Unique Foot Switch
16.With unique-designed foot switch , more convenient to take pictures.
17.Integrated Computer Imaging, Data Management and Analysis Function
18.The true color image output function;
19.With Chinese, English , Spanish and Russian language;
20.Timing of acetic acid and iodine reaction tests;
21.With 175 pictures for diagnosis; Abundant images data can be stored ;
22.Contains standard case report template, convenient for edit and print the report with real 23.color pictures.Case report can be return-visited ,searched and back-up copied.
24.Multi-functional specialized software of image processing and management, which can tab, add annotations, zoom in/out and partially magnification etc
25.With automatic evaluation and RCI biopsy indicate function;
26.Brand new data storage algorithm, which can improve the user’s browsing and searching speed
27.The data backup function, can not only improve the security of the medical record data, but also improve the storage capacity
Specifications
High Resolution and Definition Camera System
Perfect combination of optical and digital system, clearer view;
Synchronous observation through the optical scope and the computer;
1/3”high resolution, color CCD
5 speed Optical Amplification;
Video output;
Built-in scale in the observation system to measure the lesion size;
White balance auto-adjusted;
Unique spectral grating and fine-tuning
With a green filter, to facilitate observation of capillary lesions.
Unique Light Source Design
With integrative halogen light source and ring fiber, more brighter, and brightness can be adjusted;
Special Swing Arm
Stand with damping resistance design, easy adjustment at any angle (Very flexible and convenient);
Unique Foot Switch
With unique-designed foot switch , more convenient to take pictures.
Integrated Computer Imaging, Data Management and Analysis Function
The true color image output function;
With Chinese, English , Spanish and Russian language;
Timing of acetic acid and iodine reaction tests;
With 175 pictures for diagnosis; Abundant images data can be stored ;
Contains standard case report template, convenient for edit and print the report with real color pictures. Case report can be return-visited ,searched and back-up copied.
Multi-functional specialized software of image processing and management, which can tab, add annotations, zoom in/out and partially magnification etc.
With automatic evaluation and RCI biopsy indicate function;
Brand new data storage algorithm, which can improve the user’s browsing and searching speed
The data backup function, can not only improve the security of the medical record data, but also improve the storage capacity;
Specifications:
|
||||
Model
|
MSLCE09 Digital &Optical Colposcope System
|
|||
Product Configuration
|
Optical and Image System
Swing Arm Cold Halogen Light Source Software(With foot-switch and Built-in Capturing Card) Computer and LCD Screen Printer Trolley |
|||
Features |
1.High Resolution and Definition Camera System
2.Perfect combination of optical and digital system, clearer view; 3.Synchronous observation through the optical scope and the computer; 4.1/3”high resolution, color CCD 5.5 speed Optical Amplification; 6.Video output; 7.Built-in scale in the observation system to measure the lesion size; 8.White balance auto-adjusted; 9.Unique spectral grating and fine-tuning 10.With a green filter, to facilitate observation of capillary lesions. 11.Unique Light Source Design 12.lWith integrative halogen light source and ring fiber, more brighter, and brightness can be adjusted; 13.Special Swing Arm 14.Stand with damping resistance design, easy adjustment at any angle (Very flexible and convenient); 15.Unique Foot Switch 16.With unique-designed foot switch , more convenient to take pictures. 17.Integrated Computer Imaging, Data Management and Analysis Function 18.The true color image output function; 19.With Chinese, English , Spanish and Russian language; 20.Timing of acetic acid and iodine reaction tests; 21.With 175 pictures for diagnosis; Abundant images data can be stored ; 22.Contains standard case report template, convenient for edit and print the report with real 23.color pictures.Case report can be return-visited ,searched and back-up copied. 24.Multi-functional specialized software of image processing and management, which can tab, add annotations, zoom in/out and partially magnification etc 25.With automatic evaluation and RCI biopsy indicate function; 26.Brand new data storage algorithm, which can improve the user’s browsing and searching speed 27.The data backup function, can not only improve the security of the medical record data, but also improve the storage capacity
|
|||
Safety Classification
|
Photographic Device II; Light source device I
|
|||
Operation Mode
|
Intermittent Load, Continuously Operated
|
|||
Power Supply
|
AC220V±10%,50Hz±2%;
|
|||
Rated Power
|
Totally≤420VA;
Camera Device :20VA Light Source:220VA |
|||
Working Environment
|
Temp:5~40℃
|
Transportation and Storage Environment
|
Temp:-40~55℃
|
|
Relative Humidity:≤85%
|
Relative Humidity:≤95%
|
|||
Atmosphere:700~1060hpa
|
Atmosphere:500~1060hpa
|
|||
Packing Dimension |
740mm×600mm×950mm Wood Case x1 700mm×620mm×230mm(Arm Base) Cartonx1 920mm×620mm×230mm(Swing Arm)Cartonx1 520mm×155mm×460mm(LCD
Screen) Cartonx1 500mm×235mm×265mm(Printer) Cartonx1 525mm×300mm×520mm(Computer)Cartonx1 752mm×550mm×290mm(Trolley)Cartonx1 |
|||
Weight
|
NW:75kg GW:108kg
|
|||
WAT
Photographic Device |
Power Supply
|
DC 12V
|
||
Optical Lenses
|
Imaging Sensor
|
1/3”CCD
|
||
PAL/NTSC
|
NTSC
|
|||
Horizontal Resolution
|
540TVL
|
|||
Resolution Ratio
|
Level: 811; vertical: 508
|
|||
Photosensibility
|
0.05Lux F1.2
|
|||
SNR
|
50dB
|
|||
White Balance
|
Yes
|
|||
Eyepiece
Focal Length |
160mm
|
|||
Objective
Focal Length |
300mm
|
|||
Eyepiece
Magnification |
12.5X
|
|||
Field of view
|
80mm~12.5mm
|
|||
Oxyoptex
|
±5D
|
|||
Optical Amplificati on Range
|
0.4x; 0.66x; 1x; 1.5x; 2.5x
|
|||
Amplification Range
|
2.8X; 4X ;7X ;11.5X ;17X
|
|||
Focusing Range
|
40mm
|
|||
Swing Arm Length
|
330mm and 500mm
|
|||
Swing Arm Rotating Range
|
270°
|
|||
Holder Height
|
1000mm~1350mm
|
|||
Lifting Height
|
350mm
|
|||
CCD Objective Focal Length
|
65mm
|
|||
Weight
|
45Kg
|
|||
Working Distance
|
300mm
|
|||
Halogen Light Source |
Central Intensity
|
60,000Lux
|
||
Light Source
|
15V,150W Halogen Light
|
|||
Irradiated Surface Temperature
|
Lower Than 41℃
|
|||
Filter
|
Green
|
|||
Computer
|
CPU:≥2.7GHz;RAM:≥1G;Hard disk:≥250G
|
|||
Screen
|
19”LCD Screen 1024×768
|
|||
Printer
|
HP True color ink jet printer
|
|||
Working Distance
|
300mm
|
|||
Software Operating Environment
|
WINXP/WIN7 32bit
|